Expert Scientific Instrument Specialists Equipment for Printing QC
Countercurrent Chromatography
We Build Labs



The densitometer is indispensable in the pre-press industry due to
   ever greater demands of printing quality.
Triad Scientific presents these densitometers, perfect for simplicity,
   high quality and ideal suitability for the application.

REFLECTIVE DENSITOMETERS Transmission Densitometers
DR 848Reflective DensitometersDR 101

DR 848 is the most complete color reflection densitometer on the market, with capabilities never offered before in a densitometer.

It allows you to automatically measure every variable know to affect the quality and consistency of color reflection:

  • Absolute Density
  • Relative Density
  • Density Difference
  • Percent Dot
  • Dot Gain
  • Gray Balance
  • Trapping
  • Print Contrast
  • Auto Color Select
  • Simultaneous 4 color display
  • Two-step fast calibration

Do you know of any other color reflection densitometer which measures in transmission, too, on your light table?

DR848 allows you to measure also

  • Transparencies
  • Dot area percentages on screened films
  • Film densities

You will appreciate how easy the COFOMEGRA densitometer is to use:

  • DR 848 "talks" to the operator in: English, French, German, Spanish and Italian.
  • The sophistacate software gives you step by step operating direction on the easy to read Supertwist LCD
    16 x 2 character/line display.

SPECIFICATIONS

Color response: STATUS T Wide Band or DIN 16536
Measuring range: 0.00-2.5 D
Repeatability:+/- 0.01D
Linearity: +/- 0.01 D
Interinstrument Agreement:
+/- 0.02 D
Measuring area: Æ 3.5 mm
Operating temp: 10-40° C
Weight: 750 gr
Dimensions:182x76x70 mm.(LxWxH)
Accessories: calibration card Operation manual, AC Adapter/charger, Elegant carrying case

 

Designed for simple operation in checking ink uniformity and making "OK sheet" comparison, the DR 101 Color Relfective Densitometer very easy to operate, satisfies all requirements for work at offset pre-press.

It reads and displays filter densities simultaneously: C, M, Y, B.

With speed and accuracy it measures:

  • Density
  • Percent Dot Area
  • Dot Gain (Brunner and Fogra systems)
  • Gray Balance
  • Simultaneous 4 color display
  • Two-step fast calibration

Non volatile memory stores calibration data and reference values when the primary batteries are depleted or removed.

An AC adapter is provided which allows you to take readings while batteries are being recharged.

You will appreciate how easy the COFOMEGRA densitometer is to use:

DR 101 "talks" to the operator in English, French, German, Spanish and Italian.

The sophisticate software gives you step by step operating direction on the easy to read Supertwist LCD 16x2 character/line display.

SPECIFICATIONS

Color response: STATUS T Wide Band or DIN 16536
Measuring range:0.00-2.5 D
Repeatability:
+/- 0.01 D
Linearity:
+/- 0.01 D
Interinstrument Agreement:+ 0.02 D
Measuring area: Æ 3.5 mm
Warm-up time: none
Power supply:rechargeable NiCd batteries
Measuring time: 0.5 sec.
Operating temp.: 10-40° C
Weight: 750 gr.
Dimensions: 182x76x70 mm.(LxWxH)
Accessories: calibration card Operation manual, AC Adapter/charger, Elegant carrying case

OPTIONS

Polarizing filters
RS 232 interface
Printer

 

REFLECTIVE DENSITOMETERS            Transmission Densitometers

Transmission Densitometers

DT 640

DTP 642


Black and white transmission densitometer easier to operate and easier to read.

The DT640 is designed to measure also in the center of large size films whereas the traditional densitometrs are not suitable because of limited throat.

Battery operated, an impressive low price, pocket size density and dot area meter with automatic power shut off and auto-zero function.
Push button zero is a feature that gives added value to this densitometer.
Use it to make density comparison or to zero on the base of the film for very accurate dot readings.

APPLICATIONS

Measurement of large size films on a light table.
Calibration and linearization of imagesetters and scanners.
Inspect film output from processor.
Monitoring X RAY film processor and N.D.T.
Microfilm

 

SPECIFICATIONS

Measuring aperture area:3 mm
Density measuring range: 0.00 to 4.5;
precision +/- 0.01 D.
Dot area measurement range: 00 to 100%; precision +/- 1%.
Power pack: NiCd 7,2 V, 100mA/h.
Measurements per charge: approx. 2500.
Dimensions: 12.5x4.5x6.7 cm.
Weight: 250 gr.

 


The only high precision mini densitometer for imagesetter set up and inspection of film processor.

The hand-held transmission densitometer features a built in light source.

This makes density and dot area measurements more reliable and accurate than reading from units that measure on a light table.

Battery operated, low price densitometer but with performance of a laboratory desk top densitometer: it makes reliable reading of densities 0.00 to 5.5 D and very accurate measurements of dot area 00 to 100%.

 APPLICATIONS

Calibration and linearization of imagesetters and scanners.

Inspect film output from processor.

Monitoring X RAY film processor.

Microfilm

 

SPECIFICATIONS:

Measuring aperture area:3 mm
Density measuring range 0.00 to 5.5 D.
Dot area measurement range: 00 to 100%
Linearity
+/- 0.01 D
Power supply: rechargeable NiCd 7,2 V, 700 mA/h. Batteries and AC adaptor charger included.
Measurements per charge: approx. 2500.
Dimensions: 12.5x6.7x7.6 cm.
Weight: 450 gr.

 



Last update 11/12/7
Used Analytical Instruments: Atomic Absorption, FT-IR, MASS SPEC, HPLC! ©2004 Mad Joe Industries